Electric heating furnace data.
For plants prioritizing electric heating, stable running speed and low energy consumption. This design is useful when the project favors electrical utilities, predictable temperature control and a simpler fuel-supply plan.
AKS reviews strip width, thickness, material grade, TV process value, atmosphere, electrical capacity and annealing temperature before confirming the electric furnace route. The line is configured to keep heating uniformity, cooling behavior and operator control clear during daily production.
| Heating method | Electrically heated |
|---|---|
| Rated power | 360 kW |
| Line speed | 15-45 m/min |
| TV process value | 7-12 |
| Strip width options | 450 / 550 / 650 / 750 / 850 / 950 / 1050 / 1150 / 1250 / 1450 / 1780 mm |
| Thickness range | 0.03-8.0 mm |
Built for stable electric heating.
- Stable running speed and low energy consumption.
- Lower electricity consumption.
- 15% energy saving compared with comparable equipment.
- Annual inspection cycle and 1% equipment failure rate.
Specification window.
| Annealing temperature | 880-1090°C |
|---|---|
| Furnace atmosphere | N₂, H₂, or dissociated ammonia |
| Heating uniformity | ±5°C reference |
| Energy saving | Approx. 15% |
| Inspection cycle | Annual inspection |
| Failure rate | 1% |